Electronic ballast PHILIPS HF-P 136 TL-D III, HF-Performer III range, for 1 × 36 W TL-D (T8) — programmed start, flicker-free high-frequency operation, efficiency class EEI A2.
Secure payment by credit card or bank transfer.
Dispatch within 2 to 5 days with tracked delivery.
You have 14 days after receipt to make a return, in accordance with your right of withdrawal.
The PHILIPS HF-P 136 TL-D III is a high-frequency electronic ballast from the HF-Performer III range, made for 1 × 36 W TL-D (T8). It replaces the magnetic ballast + starter combination with a single unit: the lamp strikes in under a second, without flicker or hum, and the installation gains roughly a quarter in efficiency.
Its strength is the programmed start: the ballast preheats the electrodes before applying the ignition voltage. That is what lets the lamp take thousands of switching cycles without wearing the cathodes out early — decisive in a room driven by a presence detector, where an ordinary ballast kills tubes within months.
Operation at about 45 kHz, power factor 0.98 at full load, automatic restart after a lamp change, and a stated life of 100,000 hours at 40 °C. Wiring through WAGO 251 terminals: the conductor clips in, no screws. ⚠️ This ballast is not dimmable — dimming requires an HF-R (1-10 V) or HF-Ri (DALI).
Equivalents from other brands — for the same configuration (1 × 36 W TL-D (T8)), the job is done by OSRAM QUICKTRONIC QTP8 1×36, Tridonic PC 136 T8 PRO and Vossloh-Schwabe ELXc 136. ⚠️ These units drive the same lamps, but case dimensions, terminals and starting method differ between brands: check the overall size and the start type before replacing a ballast in an existing luminaire.
| Brand | PHILIPS |
|---|---|
| Type | High-frequency electronic control gear (ECG) |
| Range | HF-Performer III |
| Lamps driven | 1 × 36 W TL-D (T8) |
| Input voltage | 220-240 V, 50/60 Hz |
| Operating frequency | ≈45 kHz |
| Starting | Programmed start (electrode preheating), ≤ 0.9 s |
| Power factor | 0,98 |
| Efficiency class | EEI = A2 (CELMA BAT) |
| Ballast lifetime | ≈100,000 h at 40 °C (70,000 h at 50 °C) |
| Dimmable | No — fixed output (dimmable versions are HF-R / HF-Ri) |
| Wiring | WAGO 251 terminals, 8-9 mm strip length, 0.50-1.00 mm² |
Do I keep the starter?
No. Electronic gear handles preheating and ignition itself: the starter comes out of the circuit. When refurbishing a magnetic fitting, also remove the old ballast and the power-factor capacitor.
Can I connect a different lamp wattage?
No — stick exactly to 1 × 36 W TL-D (T8). An HF ballast is calibrated for the wattage it states: a lamp of another wattage will wear quickly, light poorly, or fail to start.
Is it dimmable?
No, this is a fixed-output version. Dimming requires an HF-R (1-10 V) or HF-Ri (DALI) ballast — a different unit, to be matched with the corresponding dimmer.
What does EEI A2 mean?
It is the energy efficiency class for control gear (CELMA classification): A2 covers efficient fixed-output electronic ballasts, well above the B and C classes of magnetic gear.